Portable ultrasound

SonoScape X10

ANVISA registration 81464759082. The X11 and the X10, each in several versions, are under the same registration and use the same user manual. Look it up at ANVISA

Portable color Doppler ultrasound with a monitor and touch screen, about 5.2 kg and 49 mm high. São Bernardo is the exclusive SonoScape distributor in the Federal District and serves Brasília.

Sales, rental and technical support in Brasília.

Prefer not to use WhatsApp? Call +55 61 3233-0536 or +55 61 3233-2958, or email contato@saobernardodf.com.br.

Request a quote for this equipment

Use

Who it is for

Portable color Doppler ultrasound, about 5.2 kg and 49 mm high without the base. For the ICU and emergency department, the manual describes the automatic B-line, SonoFast with the FAST, eFAST, LUS (lung ultrasound) and shock assessment protocols, automatic IVC and Auto VTI.

São Bernardo is the exclusive SonoScape distributor in the Federal District, with sales, rental and technical support in Brasília. Availability to be confirmed with São Bernardo.

Spec sheet

Specifications from the manual registered with ANVISA

The manual registered with ANVISA is the same as the X11's and lists no specification difference between the two. Confirm the configuration with São Bernardo.

Use

Intended use
Trained healthcare professionals, in hospitals or clinics. Applications: fetal, abdominal, pediatric, small organs (breast, testes, thyroid), cephalic (neonatal and adult), transrectal, transvaginal, peripheral vascular, cerebrovascular, musculoskeletal (conventional and superficial), cardiac (pediatric and adult), transesophageal (cardiac), laparoscopic, obstetric/gynecological and urologicalSource: manual, section 1.1
Contraindication
Not intended for ophthalmic use or any use in which the acoustic beam passes through the eyeSource: manual, section 1.2

Imaging and modes

Displays
Monitor and touch screen. The manual does not give size or resolutionSource: manual, sections 2.3.1 and 2.3.4
Lung and emergency
Automatic B-line; SonoFast, with the FAST, eFAST, LUS (lung ultrasound) and shock assessment protocolsSource: manual, sections 6.13.2, 4.4.6 and 6.14
Automatic measurements
Automatic IVC (inferior vena cava) and Auto VTISource: manual, sections 6.13.4 and 6.13.5
ECG
Optional ECG module (type BF applied part), 3 channelsSource: manual, section 9.1

Probes

Probe ports
One probe port, on the right side. More than one probe at once only with the probe extender or the manufacturer's cartSource: manual, sections 2.3.2 and 3.5
Surface probes
C1-6A, 3C-A, C613, VC6-2, 22L-A, 12L-A, 12L-B, L742, L2-9, S1-5, 4P-A, 7P-A, 8P1, P4-12, 12LI-A, 12LT-A, 10I2, 6CI-A, 6CT-A, CWD2.0 and CWD5.0Source: manual, section 11.1.1
Endocavitary probes
BCL10-5, VE9-5, 6V3, MPTEE and MPTEE miniSource: manual, section 11.1.1
Intraoperative probes
LAP8L, LAP8C and LAP8C1Source: manual, section 11.1.1
Biopsy
Biopsy bracketsSource: manual, section 11.2

Connectivity

Ports
Network, type C, USB, HDMI, S-Video and ECG, on the left sideSource: manual, section 2.3.2
Network and DICOM
Local network; DICOM: storage, print, worklist, MPPS, storage commitment, query/retrieve and structured reportsSource: manual, section 4.2 and chapter 10
HL7
Communication with HIS/RIS over the HL7 protocolSource: manual, section 4.2.5 and chapter 10

Power and environment

Dimensions
Approx. 390 mm wide, 380 mm deep and 49 mm high, without the baseSource: manual, section 2.2
Weight
Approx. 5.2 kgSource: manual, section 2.2
Battery
Built-in; at least 1.5 hours of continuous use with the batteries charged; 14.4 V; 4.7 Ah / 67.68 Wh; charges when the system is connected to the adapterSource: manual, section 3.2.2
Power supply
100 to 240 V~, 50/60 Hz; adapter with 200 VA input and 19 V, 7.9 A outputSource: manual, Appendix A
Operation
0 °C to 40 °C; relative humidity 30% to 85%, non-condensing; 700 to 1060 hPaSource: manual, Appendix A
Storage and transport
-20 °C to 55 °C; relative humidity 20% to 90%, non-condensing; 700 to 1060 hPaSource: manual, Appendix A

Classification and standards

Electrical classification
Class I with the adapter; internally powered when off the mains; type BF applied part; portable equipmentSource: manual, Appendix A
Protection against liquids
System IPX0; probe IPX7 (from the acoustic window to the junction line); footswitch IPX8Source: manual, Appendix A
Standards
IEC 60601-1, IEC 60601-1-2 and IEC 60601-2-37Source: manual, Appendix A
ANVISA registration
81464759082, class IISource: manual, cover; class II from the ANVISA lookup

Questions

Frequently asked questions

What is the ANVISA registration of the SonoScape X10?

The X10 is under ANVISA registration 81464759082, class II, held by Domo Salute Consultoria Regulatória. The same registration includes the X11, and both, in several versions, use the same user manual.

What is the difference between the X10 and the X11?

The manual registered with ANVISA is the same for both and lists no specification difference between them. Confirm the configuration with São Bernardo.

How long does the X10 battery last?

According to the manual, at least 1.5 hours of continuous use with the batteries charged (section 3.2.2). The battery is built in, 14.4 V and 67.68 Wh.

Which probes can I use with the X10?

Surface: C1-6A, 3C-A, C613, VC6-2, 22L-A, 12L-A, 12L-B, L742, L2-9, S1-5, 4P-A, 7P-A, 8P1, P4-12, 12LI-A, 12LT-A, 10I2, 6CI-A, 6CT-A, CWD2.0 and CWD5.0. Endocavitary: BCL10-5, VE9-5, 6V3, MPTEE and MPTEE mini. Intraoperative: LAP8L, LAP8C and LAP8C1 (section 11.1.1).

Does the X10 have features for lung and emergency ultrasound?

The manual describes the automatic B-line, applicable to the lung exam (section 6.13.2), and SonoFast, with the FAST, eFAST, LUS (lung ultrasound) and shock assessment protocols (sections 4.4.6 and 6.14). The list of applications in the intended use (section 1.1) does not mention lung.

Who sells, rents and supports the X10 in Brasília?

Cirúrgica São Bernardo, the exclusive SonoScape distributor in the Federal District, handles sales, rental and technical support. Availability to be confirmed with São Bernardo. Talk to our AI on WhatsApp at +55 61 99321-6835.

Source of the specifications: SonoScape, Basic User Manual X11 Exp Series/E11 Series/X10 Exp Series/E10 Series/SU11 Series/XR Series/ER Series, P/N 4710-04729A01, Aug 2025 (IFU registered with ANVISA, 81464759082; in Portuguese). Configurations and options vary. Check the configuration with São Bernardo.

Customer service

Equipping or upgrading a department?