Equipment/Ventilation/V1 and V1 Pro

VentilatorComing soon

Comen V1 and V1 Pro

Ventilators with an 8.4-inch touchscreen, invasive and non-invasive ventilation, and high-flow oxygen therapy (HFNC); the V1 offers adult and pediatric ranges, and the V1 Pro adds neonatal ranges.

Prefer not to use WhatsApp? Call +55 61 3233-0536 or +55 61 3233-2958, or email contato@saobernardodf.com.br.

Comen V1 Pro

Spec sheet

Key specifications

Display
8.4 inches, capacitive touch, 800 × 600
Ventilation modes
High flow (HFNC) and 13 invasive modes: V-A/C, P-A/C, PRVC, CPRV, V-SIMV, P-SIMV, PRVC-SIMV, CPAP/PSV, DuoVent, APRV, VS, PPS, and AMV
Oxygen concentration
21 to 100%
Gas supply
High-pressure oxygen (280 to 600 kPa, NIST or DISS connector) or low-pressure oxygen (less than 100 kPa)
Monitoring modules
Sidestream or mainstream CO2 (Comen, Respironics, or Masimo) and SpO2 (Comen, Nellcor, or Masimo)
Battery
One or two lithium-ion batteries; at least 300 minutes with one and at least 600 minutes with two
History
Graphic and tabular trends for at least 72 hours; at least 6,000 events
Weight, dimensions, and protection
Main unit: 6.5 kg and 330 × 215 × 247 mm; cart: 21.5 kg; IP34

Models

What differs between them

ItemV1V1 Pro
Tidal volumeAdult: 100 to 4,000 mL; pediatric: 20 to 300 mLAdult: 100 to 4,000 mL; pediatric: 20 to 300 mL; neonatal: 2 to 300 mL
Non-invasive modes8 modes10 modes; adds NCPAP, NIPPV, and SNIPPV
Flow in oxygen therapyAdult and pediatric: 2 to 100 L/minAdult and pediatric: 2 to 100 L/min; neonatal: 2 to 20 L/min
Respiratory rate (dual-limb circuit)1 to 100 breaths/minAdult and pediatric: 1 to 100 breaths/min; neonatal: 1 to 150 breaths/min
Flow trigger0.5 to 20 L/minAdult and pediatric: 0.5 to 20 L/min; neonatal: 0.1 to 5 L/min

V1

Tidal volume
Adult: 100 to 4,000 mL; pediatric: 20 to 300 mL
Non-invasive modes
8 modes
Flow in oxygen therapy
Adult and pediatric: 2 to 100 L/min
Respiratory rate (dual-limb circuit)
1 to 100 breaths/min
Flow trigger
0.5 to 20 L/min

V1 Pro

Tidal volume
Adult: 100 to 4,000 mL; pediatric: 20 to 300 mL; neonatal: 2 to 300 mL
Non-invasive modes
10 modes; adds NCPAP, NIPPV, and SNIPPV
Flow in oxygen therapy
Adult and pediatric: 2 to 100 L/min; neonatal: 2 to 20 L/min
Respiratory rate (dual-limb circuit)
Adult and pediatric: 1 to 100 breaths/min; neonatal: 1 to 150 breaths/min
Flow trigger
Adult and pediatric: 0.5 to 20 L/min; neonatal: 0.1 to 5 L/min

Manufacturer data: Comen.

Customer service

Equipping or upgrading a department?

Notify me